lmm@magnesiacarbonbricklmm.com

AOD Refractory Lining Solutions

An AOD (Argon Oxygen Decarburization) converter lining must withstand aggressive stainless-steel slags, intense bath agitation and localized wear around the tuyeres and slag line. LMM YOTAI develops furnace-specific refractory systems by matching materials and lining design to local service conditions.

Request a tailored AOD lining proposal
Since 2007Established specialist
90+Countries served
Complete scopeBrick · Monolithic · Functional
Furnace-specificLining design

How AOD Converter Lining Design Affects Campaign Life and Refractory Cost

Refractory cost per ton depends on campaign life, wear distribution, repair practice and material cost — not brick price alone.

AOD refractory cost per ton depends on how effectively the lining balances campaign life, local wear resistance and repair requirements. Because wear is non-uniform, zone-specific refractory selection can avoid unnecessary material consumption in lower-wear areas while protecting critical zones. Gas-flow practice, slag chemistry, temperature, heat time and steel grade can also influence lining performance and refractory consumption.

AOD Service Conditions & Lifecycle Management

AOD operates under argon-oxygen decarburization: intense gas injection, strong bath agitation and highly basic, oxidizing stainless slags.

AOD refractories are exposed to bottom or side gas injection, strong bath agitation and repeated temperature and composition changes. Wear concentrates at the tuyere zone and slag line, while the cone and bottom see different duties. Slag chemistry, gas flow, temperature and steel grade define the refractory environment, so AOD selection is zoned across tuyere, slag line, cone and bottom.

Lifecycle management

Beyond grade selection, how the lining is operated and maintained is an important factor in campaign life.

Campaign-life management

Wear monitoring, repair timing and zone-specific maintenance help extend AOD campaign life without unnecessarily increasing lining thickness or material consumption.

Tuyere condition control

Tuyere condition and gas-flow stability are monitored because local wear is strongly affected by blowing conditions and refractory exposure.

Hot repair strategy

Gunning, ramming and local patching are applied according to observed wear, remaining lining thickness and operating requirements.

Lining performance feedback

Campaign results are reviewed against wear patterns, operating conditions and refractory consumption to refine the next lining design.

AOD Converter Zone-Based Lining Design

Grade selection follows the zone — not a single brick for the whole vessel. Each zone sees a different mix of temperature, slag and mechanical load.

Zone / componentKey service conditionsTypical wear mechanismsMaterial approach
Safety liningPermanent shell protection; mainly exposed to penetration and thermal loadPenetration, thermal loadMagnesia brick (MZ-91, permanent backing)
Upper coneSlag splashing, oxidation, thermal cyclingErosion, thermal cyclingMgO-C, magnesia, doloma or other per-design grade
Slag lineRepeated slag contact, mechanical agitationSlag corrosion, penetration, erosionMgO-C, magnesia or doloma, selected according to slag chemistry and operating conditions
Tuyere / tuyere areaGas injection, strong bath agitation, high local thermal loadErosion, corrosion, thermal shockZone-specific; MgO-C where an MgO-C system is used, or MgO-enriched doloma per tuyere design
BottomMetal & slag contact, thermal cyclingCorrosion, erosionMgO-C, magnesia, doloma or other per-design grade

Note: The grade codes shown above are LMM YOTAI internal product grades and are not universal industry standards. Final grade selection is matched to furnace geometry, steel grades, slag practice, operating conditions and previous wear patterns.

Critical wear zones — The tuyere and slag-line areas require particular attention because gas injection, bath agitation and repeated slag contact accelerate local wear. Grade selection should consider tuyere design, gas flow, slag chemistry and local temperature rather than a single grade for every vessel.

Material families

The AOD Converter lining system normally combines working and safety linings with selected monolithic and shaped or prefabricated refractory components according to vessel design and operating practice.

An AOD vessel can combine MgO-C, magnesia, doloma, magnesia-calcium and MgO-Cr2O3 refractories within the same lining system. These materials provide different combinations of corrosion resistance, thermal-shock resistance, hot strength and compatibility with stainless-steel slags. Final selection depends on slag chemistry, temperature, tuyere configuration, steel grade and operating practice.Explore our full magnesia carbon brick range where MgO-C is applied.

Working & permanent lining

Magnesia carbon brick (selected zones)MG series zone-graded where MgO-C is applied in the AOD lining.
Magnesia calcium brickSelected for stainless-steel refining zones where its properties match the slag system.
Magnesia / doloma brickUsed in zones where doloma resists the slag.
MgO-Cr2O3 brickConsidered only for specific high-wear applications where slag chemistry, temperature and operating conditions are compatible.
Magnesia brick (safety lining)MZ-91 permanent backing protecting the shell.

AOD Functional Refractories & Tapping Components

Tapping components support controlled steel flow during AOD operation, while other functional refractory components are specified according to the converter design.

FunctionalConverter slide gate plateConverter tapping slide gate for controlled steel discharge and slag carryover control where this system is installed. LMM YOTAI Converter Slide Gate Plates are supplied in alumina-mullite, Al-C and ZrO2 grades with matched mechanisms (LMM-201 / 301 / 401 / 501) for different converter sizes.

What We Need to Design the AOD Converter Lining

The more operating data you share, the closer the proposal matches your vessel.

Vessel geometry and capacity (working volume, cone angle).
Tuyere configuration and gas-flow practice (Ar/O2 ratio, flow rate).
Steel grades and production mix (stainless, low-carbon, special steel).
Slag chemistry and basicity (Cr2O3, FeO, CaO/SiO2, MgO).
Tap temperature and heat time.
Current lining map and campaign life.
Wear map, repair records and existing refractory grades.
Refractory budget and target campaign life.

LMM YOTAI AOD Converter Refractory Solution

For AOD Converter applications, LMM YOTAI combines furnace-specific lining design with coordinated supply of brick, monolithics and functional refractories across the full refractory scope.

Engineering

Furnace-specific lining design, zone mapping and reline support.

Material coordination

Matched grades across brick, monolithics and functional refractories.

Supply

Coordinated production, inspection and delivery across the full refractory scope.

Technical support

Installation guidance, repair recommendations and campaign follow-up.

Trusted by steelmakers worldwide

Get a tailored AOD Converter lining proposal

LMM YOTAI engineers spec each lining to your furnace and steel grades, then supply brick, monolithics, functional refractories and installation materials as one coordinated package.

Request a proposal

Frequently asked questions

Practical questions from operators specifying a new AOD Converter lining or reline.

AOD refractory grades are selected by zone rather than by applying one material throughout the vessel. The selection depends on slag chemistry, temperature, bath agitation, tuyere configuration, steel grade and operating practice. MgO-C, doloma, magnesia and other refractory grades may be used where their properties match the local service conditions.

Tuyere geometry, gas-flow conditions, bath agitation and local thermal load all influence refractory wear around the tuyere area. The refractory grade and thickness should therefore be matched to the tuyere configuration and operating practice rather than selected independently from the vessel design.

Managing slag chemistry and temperature, controlling gas flow and tuyere condition, scheduled gunning/ramming repair, wear monitoring and correct zone-by-zone grade selection are the main levers.

Yes. LMM YOTAI can coordinate the refractory package to your vessel design and operating requirements, including bricks, monolithics, selected functional refractories and technical support.

Stainless-steel refining produces basic, oxidizing slags that can contribute to refractory corrosion, penetration and oxidation. Slag basicity, Cr2O3 and FeO levels, temperature and overall slag practice should therefore be considered when selecting materials for each zone. Depending on the service conditions, MgO-C, doloma, magnesia or other compatible grades may be specified.

Related furnace solutions

Lining systems for the rest of the steelmaking route.

SolutionEAFLining system & zone-to-grade map
SolutionBOF ConverterLining system & zone-to-grade map
SolutionLadle & LFLining system & zone-to-grade map
SolutionVOD / VODCLining system & zone-to-grade map
SolutionGOR ConverterLining system & zone-to-grade map
SolutionRH DegasserLining system & zone-to-grade map

Refractory Catalogue & Grade Datasheets

Full grade datasheets and the LMM YOTAI refractory brochures support specification and reline planning.

BrochureRefractory Materials Main brick & monolithic grades
BrochureFunctional Refractories Slide Gate & Nozzle
BrochureGraphite ElectrodeElectrode scope

Comprehensive solution of Refractory for steelmaking

Fill out the form below, and we will be in touch shortly.
Contact Information