lmm@magnesiacarbonbricklmm.com

BOF Converter Refractory Lining Solutions

A Basic Oxygen Furnace (BOF) converter lining must withstand high temperature, slag attack, oxidation, mechanical wear and localized impact throughout the vessel. LMM YOTAI develops furnace-specific refractory systems by matching materials, zone grading and lining design to vessel geometry, steelmaking practice and local wear conditions.

Request a tailored BOF lining proposal
Since 2007Established specialist
90+Countries served
Complete scopeBrick · Monolithic · Functional
Furnace-specificLining design

How BOF Converter Lining Design Affects Campaign Life and Refractory Cost

Refractory cost per ton depends on campaign life, wear distribution, repair practice and material cost — not brick price alone.

BOF lining cost per ton depends mainly on campaign life and repair practice, not brick price alone. The trunnion and slag-line regions are among the most heavily worn zones in many BOF converters, but the exact wear map depends on vessel geometry, blowing practice and operating conditions. Correct zone-by-zone MgO-C grading plus scheduled repair are important levers on cost per ton. Blowing practice, hot-metal temperature and chemistry, slag basicity and tap temperature also affect total converter cost.

BOF Converter Refractory Lining Structure

A BOF Converter refractory system is a layered lining combined with repair and functional components. The main elements are:

System elementRole in the lining system
Steel shellVessel structure and outer boundary.
Safety / permanent liningPermanent or longer-life magnesia backing (typically MZ-91) that protects the shell.
Working liningConsumable MgO-C layer, zone-graded by local wear duty.
Repair lining / gunning & rammingApplied during campaigns to restore local thickness and extend life.
Functional componentsTap-hole slide gate, nozzle, bottom-stirring plug and slag-retention device where used.

Correct interaction between these layers — not any single brick — is an important factor in campaign life and refractory cost.

BOF Converter Refractory Wear Mechanisms

A BOF lining wears through several mechanisms at once; attributing loss to one cause oversimplifies it. The main mechanisms and their typical drivers:

Wear mechanismTypical contributing factors
Slag corrosionFeO, slag chemistry, basicity, temperature
OxidationOxygen exposure, carbon oxidation, blowing conditions
ErosionSlag/metal movement and high-velocity flow
Mechanical wearScrap impact, vessel movement, local impact
Thermal / mechanical damageThermal cycling, temperature gradients, stress
Localized wearOxygen jet impingement, geometry and operating practice

BOF Service Conditions & Lifecycle Management

A BOF converter lining faces rapid, high-temperature campaigns with intense molten-steel and slag contact.

BOF refractories see strong mechanical impact during blowing and charging, oxidation from oxygen-lance operation and high thermal, chemical and mechanical loads at the trunnion, slag line and tap pad. Where fitted, bottom stirring tuyeres or porous plugs introduce additional localized duty. Gas flow, lance practice, slag basicity and tapping temperature all change the local refractory environment, so BOF lining selection is normally zoned across the vessel.

Lifecycle management

Beyond grade selection, how the lining is operated and maintained is an important factor in campaign life.

Campaign-life management

Residual lining thickness, laser/profile measurements where available, wear mapping, repair timing and zone-specific maintenance help track campaign condition and extend BOF campaign life without unnecessarily increasing lining thickness or material consumption.

Trunnion & slag-line control

Trunnion and slag-line condition are tracked because these areas can experience severe combined slag corrosion, oxidation, splashing and mechanical wear.

Hot repair strategy

Gunning, ramming and local patching are applied according to observed wear, remaining lining thickness and operating requirements.

Lining performance feedback

Campaign results are reviewed against wear patterns, operating conditions and refractory consumption to refine the next lining design.

BOF Converter Zone-Based Lining Design

Grade selection follows the zone — not a single brick for the whole vessel. Each zone sees a different mix of temperature, slag and mechanical load.

Zone / componentKey service conditionsTypical wear mechanismsMaterial approach
Safety liningPermanent shell protection; mainly exposed to penetration and thermal loadPenetration, thermal loadMagnesia brick (MZ-91, permanent backing)
BottomBottom design, stirring arrangement, metal/slag flow and localized wearErosion, corrosion, thermal/mechanical damageZone-selected MgO-C, with grade and construction adapted to bottom design (typical LMM selection: MT-14A / MT-16A)
Melting bathBath agitation, high temperature, slag contactSlag corrosion, oxidation, erosion, thermomechanical stressZone-selected MgO-C such as MT-14A, depending on local wear and operating conditions
Slag line / trunnion areaCombined slag corrosion, oxygen-related oxidation, splashing and blowing impactSlag corrosion, oxidation, erosion, penetrationHigh-grade MgO-C (MT-14A, MT-16A)
Tapping sideTap stream, slagErosion, corrosion, thermal/mechanical stressZone-selected MgO-C such as MT-14A, depending on tap-side wear conditions
Charge pad / charging sideScrap impactImpact, spallingMgO-C (MT-12A, MT-14A)
Upper coneSlag/metal splash, oxidation, thermal cyclingErosion, oxidation, thermal cyclingZone-selected MgO-C such as MT-10A
Tap-hole areaHigh-velocity steel/slag flow, thermal cyclingErosion, corrosion, thermal/mechanical stressZone-selected dense MgO-C or other tap-hole refractory materials, depending on tap-hole design, flow conditions and maintenance practice

Note: The grade codes shown above are LMM YOTAI internal product grades and are not universal industry standards. Final grade selection is matched to furnace geometry, steel grades, slag practice, operating conditions and previous wear patterns.

Critical wear zones — The trunnion and slag-line areas are among the most heavily worn zones in many BOF converters because they combine slag corrosion, oxygen-related oxidation, splashing and blowing impact. High-performance MgO-C (MT-14A / MT-16A) plus tight zone grading is an important factor in controlling localized wear and optimizing campaign life; disciplined repair practice there protects the whole lining.

Material families

A BOF Converter lining system normally combines working and safety linings with selected monolithic and shaped or prefabricated refractory components according to vessel design and operating practice.

Magnesia carbon brick is the principal refractory material used in many BOF working linings. LMM YOTAI's MT series (MT-10A through MT-16A) covers the full gradient from the upper cone to the high-wear trunnion and bottom zones. Correct zone-based grade selection is an important factor in controlling localized wear and optimizing campaign life, and our technicians tune the selection to your hot-metal temperature and chemistry and blowing practice. See our full magnesia carbon brick range.

Working & permanent lining

Magnesia carbon brick (working lining)MT-10A to MT-16A zone-graded MgO-C — the dominant BOF working lining.
Magnesia brick (safety lining)MZ-91 permanent backing protecting the shell.
Ramming & monolithic mixesBottom, lip-ring and installation gunning / ramming materials.

BOF Functional Refractories & Tapping Components

Functional refractories and tapping components support controlled steel flow, bottom stirring and slag retention during BOF operation.

FunctionalConverter slide gate plateRefractory slide gate plate for controlled steel tapping. LMM YOTAI Converter Slide Gate Plates are supplied in alumina-mullite, Al-C and ZrO2 grades with matched mechanisms (LMM-201 / 301 / 401 / 501) for different converter sizes.
FunctionalConverter nozzleTap-hole nozzle sleeve for the converter. LMM YOTAI supplies converter nozzle and tap-hole sleeve refractories matched to the tapping design.
FunctionalConverter porous plug brickBottom stirring component for controlled gas injection in BOF steelmaking. LMM YOTAI porous plug bricks (PP-A / PP-B / PP-C series) are supplied for bottom stirring where the vessel is equipped with a compatible gas-injection system.

What We Need to Design the BOF Converter Lining

The more operating data you share, the closer the proposal matches your vessel.

Converter capacity / vessel dimensions
Current lining map and brick dimensions
Steel grades and production mix
Hot-metal temperature and chemistry
Slag chemistry, basicity and flux practice
Oxygen lance and blowing practice
Current campaign life
Wear map / repair records and existing refractory grades

LMM YOTAI BOF Converter Refractory Solution

For BOF Converter applications, LMM YOTAI combines furnace-specific lining design with coordinated supply of brick, monolithics and shaped or prefabricated refractory components across the full refractory scope.

Engineering

Furnace-specific lining design, zone mapping and reline support.

Material coordination

Matched grades across brick, monolithics and shaped or prefabricated refractory components.

Supply

Coordinated production, inspection and delivery across the full refractory scope.

Technical support

Installation guidance, repair recommendations and campaign follow-up.

How we develop your lining

A lining proposal is built from your operating data, not a catalogue default.

01 — Review operating data

Campaign life, heat data, steel grades, slag chemistry and operating practice.

02 — Map refractory wear

Identify trunnion, slag-line, charge-pad, tap-pad, bottom and cone wear.

03 — Select zone-specific grades

Match MgO-C grades and supporting materials to local service conditions.

04 — Define lining structure

Set brick grades, dimensions, thickness and construction scheme.

05 — Coordinate supply and installation

Working lining, safety lining, gunning/ramming materials and functional components.

06 — Review campaign performance

Use wear and repair data to refine the next lining campaign.

Trusted by steelmakers worldwide

Get a tailored BOF Converter lining proposal

LMM YOTAI engineers spec each lining to your furnace and steel grades, then supply brick, monolithics, functional refractories and installation materials as one coordinated package.

Request a proposal

Frequently asked questions

Practical questions from operators specifying a new BOF Converter lining or reline.

A typical BOF converter lining combines a permanent/safety lining with a zone-graded MgO-C working lining. Depending on vessel design and process configuration, the refractory system may also include monolithic repair materials and functional components for tapping and bottom stirring.

The trunnion and slag-line regions are commonly among the highest-wear areas, but the actual wear map varies with vessel geometry, oxygen-lance position, slag chemistry, blowing practice and repair methods. Charge pads, tap pads, the bottom and other local zones can also experience significant wear.

The trunnion area normally requires a high-performance MgO-C grade because of localized oxygen exposure, slag/metal splashing and mechanical or thermomechanical wear. LMM YOTAI may select MT-14A, MT-16A or another suitable grade according to vessel geometry, wear history and operating conditions.

The safety lining (typically MZ-91 magnesia brick) is a permanent backing that protects the shell; the working lining is the consumable MgO-C layer replaced during reline.

BOF lining life can be improved by controlling hot-metal temperature and chemistry, managing slag basicity and oxidation conditions, optimizing oxygen-blowing practice, using appropriate zone-based refractory grades, monitoring residual lining thickness and applying timely repair.

Yes. We deliver the full converter lining — brick, ramming mixes (D-6), and installation materials (N-1, MS-91) — as one coordinated package with technical support. These codes are LMM YOTAI internal product references for application-specific materials, not universal industry grades.

Related furnace solutions

Lining systems for the rest of the steelmaking route.

SolutionEAFLining system & zone-to-grade map
SolutionLadle & LFLining system & zone-to-grade map
SolutionAOD ConverterLining system & zone-to-grade map
SolutionVOD / VODCLining system & zone-to-grade map
SolutionGOR ConverterLining system & zone-to-grade map
SolutionRH DegasserLining system & zone-to-grade map

Refractory Catalogue & Grade Datasheets

Full grade datasheets and the LMM YOTAI refractory brochures support specification and reline planning.

BrochureRefractory Materials Main brick & monolithic grades
BrochureFunctional Refractories Slide Gate & Nozzle
BrochureGraphite ElectrodeElectrode scope

Comprehensive solution of Refractory for steelmaking

Fill out the form below, and we will be in touch shortly.
Contact Information