A GOR (Gas-Oxygen Refining) converter lining must withstand intense bottom gas injection, high-temperature molten steel and slag attack, thermal cycling, and localized wear around the bottom-blowing tuyeres and slag-contact zones. LMM YOTAI develops furnace-specific refractory systems by matching materials and lining design to local service conditions.
Request a tailored GOR lining proposalRefractory cost per ton depends on campaign life, wear distribution, repair practice and material cost — not brick price alone.
GOR lining cost per ton is strongly influenced by campaign life, bottom-tuyere durability and the distribution of wear across the furnace bottom and working lining. Localized wear can develop around the bottom-blowing tuyere zone, while slag corrosion, thermal cycling, molten-steel flow and operating practice also affect refractory consumption. Dedicated tuyere-area grades, zone-based material selection and targeted repair are therefore used together rather than relying on a single refractory grade throughout the vessel.

A GOR converter combines top-and-bottom combined blowing, so it carries both lance and bottom gas-injection duties.
GOR refractories see concentrated thermal, chemical and mechanical load at the bottom-blowing tuyere zone, while the barrel, slag line and other bottom areas see different duties. Blowing practice, tuyere arrangement, slag chemistry and steel grade define the refractory environment, so GOR lining selection is zoned across the tuyere, bottom, barrel and slag-contact zones.
Beyond grade selection, how the lining is operated and maintained is an important factor in campaign life.
Wear monitoring, repair timing and zone-specific maintenance help extend GOR campaign life without unnecessarily increasing lining thickness or material consumption.
Bottom-tuyere condition is monitored because gas injection creates concentrated thermal, chemical and mechanical loads around the tuyere and adjacent furnace-bottom areas.
Gunning, ramming or local patching can be selected according to observed wear, remaining lining thickness and operating requirements.
Campaign results are reviewed against wear patterns, operating conditions and refractory consumption to refine the next lining design.
Grade selection follows the zone — not a single brick for the whole vessel. Each zone sees a different mix of temperature, slag and mechanical load.
| Zone / component | Key service conditions | Typical wear mechanisms | Material approach |
|---|---|---|---|
| Safety lining | Permanent shell protection; mainly exposed to penetration and thermal load | Penetration, thermal load | Magnesia brick (MZ-91, permanent backing) |
| Tuyere / tuyere area | Bottom gas injection, high local thermal and mechanical load, slag and molten-steel contact | Erosion, corrosion, thermal shock | Dedicated MgO-C (MGT-8A) where an MgO-C system is appropriate |
| Other bottom area | Bath contact, moderate agitation | Corrosion, erosion | Zone-selected MgO-C (MGT-8B, MGT-8C) or other compatible basic refractory systems |
| Barrel / upper cone | Slag splash, thermal cycling | Erosion, thermal cycling | Zone-selected MgO-C (MG-20A) or other compatible basic refractory |
| Slag-contact zone | Repeated slag contact and thermal cycling | Slag corrosion, erosion | Zone-selected basic refractory or monolithic repair material (e.g. MT-12A) |
| Bottom repair / monolithic zones | Thermal cycling, metal and slag contact | Corrosion, erosion, thermal shock | Ramming and repair materials (DY-1, D-6, TC-1) |
Note: The grade codes shown above are LMM YOTAI internal product grades and are not universal industry standards. Final grade selection is matched to furnace geometry, steel grades, slag practice, operating conditions and previous wear patterns.
Critical wear zones — The bottom-blowing tuyere and adjacent furnace-bottom areas require particular attention because gas injection creates concentrated thermal, chemical and mechanical stresses. Actual wear distribution depends on tuyere arrangement, gas flow, slag chemistry, steel grade, furnace-bottom design and operating practice. A dedicated tuyere-area grade such as MGT-8A may therefore be used within an MgO-C-based system, while adjacent bottom and working zones are graded according to their individual service conditions.
The GOR Converter lining system normally combines working and safety linings with selected monolithic and shaped or prefabricated refractory components according to vessel design and operating practice.
In a GOR vessel, magnesia-carbon, magnesia-calcia and other compatible basic refractory systems may be used across the working lining, with grades selected according to local wear conditions. Dedicated grades can be specified around the tuyere zone, while other bottom, barrel and slag-contact areas are matched to their individual thermal and chemical duties. Where MgO-C is applied, explore our magnesia carbon brick range.
Functional refractories and tapping components support controlled steel flow, bottom stirring and slag retention during GOR operation.
The more operating data you share, the closer the proposal matches your vessel.
For GOR Converter applications, LMM YOTAI combines furnace-specific lining design with coordinated supply of brick, monolithics and shaped or prefabricated refractory components across the full refractory scope.
Furnace-specific lining design, zone mapping and reline support.
Matched grades across brick, monolithics and shaped or prefabricated refractory components.
Coordinated production, inspection and delivery across the full refractory scope.
Installation guidance, repair recommendations and campaign follow-up.
Trusted by steelmakers worldwide
LMM YOTAI engineers spec each lining to your furnace and steel grades, then supply brick, monolithics, functional refractories and installation materials as one coordinated package.
Request a proposalPractical questions from operators specifying a new GOR Converter lining or reline.
A dedicated MgO-C grade such as MGT-8A may be specified for the bottom-blowing tuyere area, while other zones are selected according to their individual thermal, chemical and mechanical duties.
The bottom-blowing tuyere and adjacent furnace-bottom areas can experience particularly severe localized wear because gas injection creates concentrated thermal, chemical and mechanical loads. Actual wear patterns depend on tuyere layout, gas flow, slag chemistry and operating practice.
Tuyere grade selection starts with tuyere design, gas flow, steel grade, slag chemistry, thermal cycling and previous wear patterns. Where an MgO-C system is appropriate, LMM YOTAI may specify MGT-8A for the tuyere/tuyere-area zone and different grades for adjacent bottom areas.
Tuyere-grade selection, blowing-practice control, slag-chemistry management and scheduled gunning/ramming repair are the main levers.
Yes. We supply brick, monolithics (MT-12A, DY-1, D-6, TC-1) and installation materials together, plus engineering support for lining design and reline.
Lining systems for the rest of the steelmaking route.
Full grade datasheets and the LMM YOTAI refractory brochures support specification and reline planning.